RECORDINGhttp://www.sweetwater.com/click/recorg/dfinancing/ebillme/  
Our Sponsors
Pro Audio Products

http://www.auralex.com/

Recording.org
PRO SHOP
Categories
· Accessories
· Compressors / Limiters / Gates
· Equalizers
· Micing Systems & Spitters
· Microphones
· Mixers/ Consols
· Modular Rack Systems
· Monitor
· Preamps
· Processors
· Recording Channels
· Summing Amps
Pro Shop
Random Audio Product

C400
$900.00
Members Support
RO CLUB
You are not subscriber of RECORDING. You can subscribe from here now!
User Info, Site Stats
We received
79948626
page views since March 15, 2004
Recording Org
Navigation Map
recording.jpg HomeShow/Hide content
Access restricted to our members Feedback (contact us)
tree-L.gif Recommend Us
· Advertise Here
keyword ads
· Feeds
forums1.jpg DiscussionsShow/Hide content
tree-T.gif Forum RULES
tree-T.gif Forum Search
tree-T.gif Your Account
tree-L.gif Lost Password
pronews.gif Business SectionShow/Hide content
tree-T.gif NewsNew content !
tree-T.gif Topics
Access restricted to our members Submit News
· AdvertisingShow/Hide content
Access restricted to our members Advertising Contact UsShow/Hide content
tree-T.gif keyword ads
tree-L.gif Pro Audio
Linking System
Access restricted to our members Feedback (contact us)
Access restricted to our members News Search
· The Pro Shop
Gear 4 Sale
icon_poll.gif ContentShow/Hide content
tree-T.gif Reviews & Features
tree-T.gif Stories Archive
Access restricted to our members Music_Business_Links
icon_members.gif InfoShow/Hide content
fleche.gif Books
tree-T.gif FAQ
Access restricted to our members Feedback (contact us)
fleche.gif Glossary
tree-T.gif Recommend Us
tree-T.gif Statistics
Access restricted to our members News Search
tree-T.gif Surveys
tree-L.gif Your Account
Latest Survey
Buying gear direct, would you support this?

YES, save me 10/20/40% and buy gear direct
No, add extra shipping costs, add dealer profit



Results
Polls

Votes: 233
Comments: 8
Mix News
·51st Annual Grammy® AwardsNominees Announced
·Immediate Music Launches 'IM Bands' Division
·Shure Announces Wireless System Rebate
·51st Annual Grammy Nominations Announced
·Schyman Composes 'Destroy All Humans' Third Installment

read more...©
  Forum FAQ    Search    Profile    Log in to check your private messages    Log in
  Your url ad could be here!

 
Post new topicReply to topic
View previous topic Log in to check your private messages View next topic
Author Message
MadMax
Recording Org
Pro Audio Group



Joined: Mar 18, 2001
Posts: 1340
Location: Sunny & warm NC


------------

Books To Read
Your Forum Posts

gimmie gear

PostPosted: Sat Apr 22, 2006 9:38 am Reply with quoteBack to top

I met with a concrete contractor the other day to discuss the floor of the studio, the offices and a few other smaller pours around the property.

I'm sure that he's got both our best interests at heart... (Read, he doesn't want to price himself out of work.)

I had been designing the studio floor slabs as 8 inch rebar reinforced slab, with 10-12 inch footers. (12 inch on the front control room wall)

He countered with a flat 6 inch fiber reinforced concrete slab w/ .5 inch rebar. He's assured me that this will more than make the inspectors happy, and should be less susceptable to cracking as the weight of the footers is what adds stress to the center of the slab load... which has a tendancy to promote cracking.

Any opinions?

Also, would I benefit from closing in the rebar pattern from 10 inches to 6 inches?

To review... The load will be 2x6 walls with .75 mdf and two layers of 5/8 fire rated gypsum. Ceilings will be 2x6 w/2-3 layers of 5/8 fire rated gypsum.

Thanx,
Max

_________________
The insanity can be seen in bigger pix and greater detail at: http://www.dmmobile.com

"A committee is a cul-de-sac down which ideas are lured and then quietly strangled." -- Sir Barnett Cocks (1907 - 1989)
View user's profileSend private messageSend e-mailVisit poster's website
StevenColbert
Recording Org
Pro Audio Group



Joined: Feb 12, 2006
Posts: 170


------------

Books To Read
Your Forum Posts

gimmie gear

PostPosted: Sat Apr 22, 2006 11:23 am Reply with quoteBack to top

Typically concrete floors are poured at 4". I believe that is the building code. So anything over 4" is more than enough. And should not crack.
If the floor guy is someone who you know or "feel" you can trust. Let him do as he thinks is best for you (both). Obviously just let him know what your main concerns are.
View user's profileSend private message
Rod Gervais
Moderator



Joined: Jun 8, 2003
Posts: 3188
Location: Central Village, CT


------------

Books To Read
Your Forum Posts

gimmie gear

PostPosted: Sat Apr 22, 2006 11:44 am Reply with quoteBack to top

MadMax wrote:
I met with a concrete contractor the other day to discuss the floor of the studio, the offices and a few other smaller pours around the property.

I'm sure that he's got both our best interests at heart... (Read, he doesn't want to price himself out of work.)

I had been designing the studio floor slabs as 8 inch rebar reinforced slab, with 10-12 inch footers. (12 inch on the front control room wall)

He countered with a flat 6 inch fiber reinforced concrete slab w/ .5 inch rebar. He's assured me that this will more than make the inspectors happy, and should be less susceptable to cracking as the weight of the footers is what adds stress to the center of the slab load... which has a tendancy to promote cracking.

Any opinions?

Also, would I benefit from closing in the rebar pattern from 10 inches to 6 inches?

To review... The load will be 2x6 walls with .75 mdf and two layers of 5/8 fire rated gypsum. Ceilings will be 2x6 w/2-3 layers of 5/8 fire rated gypsum.


Max,

He's right that an 8" slab is overkill in this case - and I won't use a footing under a slab - but I would not use a 6" thick slab to carry bearing walls either.

I would want a 6" thick slab - the #4 drb is ok - but make sure he uses chairs to keep them in the top 1/3 of the slab (the bars in a non structural slab are actually shrinkage control) 16" grid is fine = but where the walls will rest you want a 12" thick haunch - which is integral with the slab - and thus places no un-natural sources on the slab itself.

If you need a detail I can email you one.

Rod

_________________
Rod Gervais
Acoustics Moderator Sometimes - late at night..... when the wind whips
through the trees........ and the moon shines bright in my
face......... I think deep thoughts.......... and my head hurts.
View user's profileSend private messageSend e-mail
MadMax
Recording Org
Pro Audio Group



Joined: Mar 18, 2001
Posts: 1340
Location: Sunny & warm NC


------------

Books To Read
Your Forum Posts

gimmie gear

PostPosted: Sat Apr 22, 2006 1:09 pm Reply with quoteBack to top

Rod,

Please forgive my english... I'm an American Confused I VERY incorrectly used footer... I really meant haunch. - DOH!

So you ARE advising a 12" haunch on the perimeter of each pad.

I don't see how I could get away without one... thus my questioning the contractor not insisting on their use. Even after informing him of the weights involved in the walls and ceiling, he didn't think that the uniform 6" pads would have a problem with the wall weight.

I showed him the drawings and he seemed to understand the plans, but I just get the feeling he didn't comprehend the total weights involved.

I'd love a detail - I'm using TurboCAD if that's any help. THANX!!!!!!!!

Max

_________________
The insanity can be seen in bigger pix and greater detail at: http://www.dmmobile.com

"A committee is a cul-de-sac down which ideas are lured and then quietly strangled." -- Sir Barnett Cocks (1907 - 1989)
View user's profileSend private messageSend e-mailVisit poster's website
Rod Gervais
Moderator



Joined: Jun 8, 2003
Posts: 3188
Location: Central Village, CT


------------

Books To Read
Your Forum Posts

gimmie gear

PostPosted: Sat Apr 22, 2006 3:16 pm Reply with quoteBack to top

Max,

detail is in your email inbox.........

If he gives you a hard time - tell him to just be quiet and do it........ he's absolutely wrong about this causing problems.

Rod

_________________
Rod Gervais
Acoustics Moderator Sometimes - late at night..... when the wind whips
through the trees........ and the moon shines bright in my
face......... I think deep thoughts.......... and my head hurts.
View user's profileSend private messageSend e-mail
David French
Moderator



Joined: Jun 19, 2002
Posts: 2844
Location: Indiana


------------

Books To Read
Your Forum Posts

gimmie gear

PostPosted: Sat Apr 22, 2006 3:43 pm Reply with quoteBack to top

Man, this seems like a pretty elementary matter for a pro to be wrong on. Maybe you should find someone else?

_________________
David M. French
RO Digital Audio Recording Moderator
View user's profileSend private messageSend e-mail
Rod Gervais
Moderator



Joined: Jun 8, 2003
Posts: 3188
Location: Central Village, CT


------------

Books To Read
Your Forum Posts

gimmie gear

PostPosted: Sat Apr 22, 2006 5:48 pm Reply with quoteBack to top

David French wrote:
Man, this seems like a pretty elementary matter for a pro to be wrong on. Maybe you should find someone else?


David,

the fact that someone is a pro at pouring concrete does not suggest that he/she is a pro at structural design.

The same way that being a professional car driver doesn't mean you could design an engine - and most pro recording engineers can't build a recording console or design their own compressors, pre-amps - or effects boxes.

Sincerely,

Rod

_________________
Rod Gervais
Acoustics Moderator Sometimes - late at night..... when the wind whips
through the trees........ and the moon shines bright in my
face......... I think deep thoughts.......... and my head hurts.
View user's profileSend private messageSend e-mail
David French
Moderator



Joined: Jun 19, 2002
Posts: 2844
Location: Indiana


------------

Books To Read
Your Forum Posts

gimmie gear

PostPosted: Sat Apr 22, 2006 6:08 pm Reply with quoteBack to top

Got it, thanks.

_________________
David M. French
RO Digital Audio Recording Moderator
View user's profileSend private messageSend e-mail
MadMax
Recording Org
Pro Audio Group



Joined: Mar 18, 2001
Posts: 1340
Location: Sunny & warm NC


------------

Books To Read
Your Forum Posts

gimmie gear

PostPosted: Sat Apr 22, 2006 9:38 pm Reply with quoteBack to top

Rod,

Got the file... THANX!!

That's exactly what I figured - 12" depth...

Just out of curosity, what thickness of expansion joint would you recommend?

Max

_________________
The insanity can be seen in bigger pix and greater detail at: http://www.dmmobile.com

"A committee is a cul-de-sac down which ideas are lured and then quietly strangled." -- Sir Barnett Cocks (1907 - 1989)
View user's profileSend private messageSend e-mailVisit poster's website
Rod Gervais
Moderator



Joined: Jun 8, 2003
Posts: 3188
Location: Central Village, CT


------------

Books To Read
Your Forum Posts

gimmie gear

PostPosted: Sun Apr 23, 2006 7:19 am Reply with quoteBack to top

MadMax wrote:
Rod,

Got the file... THANX!!

That's exactly what I figured - 12" depth...

Just out of curosity, what thickness of expansion joint would you recommend?

Max


Max,

1" is fine.

Rod

_________________
Rod Gervais
Acoustics Moderator Sometimes - late at night..... when the wind whips
through the trees........ and the moon shines bright in my
face......... I think deep thoughts.......... and my head hurts.
View user's profileSend private messageSend e-mail
MadMax
Recording Org
Pro Audio Group



Joined: Mar 18, 2001
Posts: 1340
Location: Sunny & warm NC


------------

Books To Read
Your Forum Posts

gimmie gear

PostPosted: Sun Apr 23, 2006 8:36 am Reply with quoteBack to top

Rod,

Pandora's box... sorry.

Is it code that the sand be there?

My current soil structure... AFAIK...

1. Gravel - 1"
2. Clay/earth

The plan so far then...

1. Starting at existing grade, dig 6 inches for the haunches, plus 2 inches for poly/gravel.
2. Place 2" of gravel in bottom of haunch.
3. Lay poly in haunches and over the rest of the pad(s)
4. Rebar in 16" grid on 4" saddles
4a. Rebar 2" from bottom of haunch (as per drawing)
5. Pour the pads to 6" above existing grade.

1" expansion joint along exterior perimeter.

As for the different pads. I can save a pure-T butt load o' money if I could do one pour. But I don't see how I could do it and not leave some sort of steel framing/forms in the floor.

Is there a way to do one pour? Or am I just plain stupid? (A loaded question for sure, huh?)

Thanx,

Max

_________________
The insanity can be seen in bigger pix and greater detail at: http://www.dmmobile.com

"A committee is a cul-de-sac down which ideas are lured and then quietly strangled." -- Sir Barnett Cocks (1907 - 1989)
View user's profileSend private messageSend e-mailVisit poster's website
Rod Gervais
Moderator



Joined: Jun 8, 2003
Posts: 3188
Location: Central Village, CT


------------

Books To Read
Your Forum Posts

gimmie gear

PostPosted: Sun Apr 23, 2006 10:14 am Reply with quoteBack to top

MadMax wrote:
Rod,

Pandora's box... sorry.

Is it code that the sand be there?

My current soil structure... AFAIK...

1. Gravel - 1"
2. Clay/earth

The plan so far then...

1. Starting at existing grade, dig 6 inches for the haunches, plus 2 inches for poly/gravel.
2. Place 2" of gravel in bottom of haunch.
3. Lay poly in haunches and over the rest of the pad(s)
4. Rebar in 16" grid on 4" saddles
4a. Rebar 2" from bottom of haunch (as per drawing)
5. Pour the pads to 6" above existing grade.


The sand isn't a code requirement - it's an isolation requirement.

The 2" gravel above clay is not going to do a good job of isolating the slabs - sand is a great damping material.

Quote:
1" expansion joint along exterior perimeter.


good

Quote:
As for the different pads. I can save a pure-T butt load o' money if I could do one pour. But I don't see how I could do it and not leave some sort of steel framing/forms in the floor.


No problem - you can layout the different slabs - and install the expansion joint using steel form pins - then just remove the form pins and fill the holes with slurry after pouring. We do that all the time.

Sincerely,

Rod

_________________
Rod Gervais
Acoustics Moderator Sometimes - late at night..... when the wind whips
through the trees........ and the moon shines bright in my
face......... I think deep thoughts.......... and my head hurts.
View user's profileSend private messageSend e-mail
MadMax
Recording Org
Pro Audio Group



Joined: Mar 18, 2001
Posts: 1340
Location: Sunny & warm NC


------------

Books To Read
Your Forum Posts

gimmie gear

PostPosted: Sun Apr 23, 2006 10:50 am Reply with quoteBack to top

Rod Gervais wrote:
The sand isn't a code requirement - it's an isolation requirement.

The 2" gravel above clay is not going to do a good job of isolating the slabs - sand is a great damping material.


I mis-quoted the depth of the existing gravel. It's not 1", it's more like 6-8" of crush-n-run... I just went out and tried to dig a test hole w/o much luck. Jebus is that stuff compacted and HARD!

Would 4" of sand in the haunch alone be sufficient?

Quote:
No problem - you can layout the different slabs - and install the expansion joint using steel form pins - then just remove the form pins and fill the holes with slurry after pouring. We do that all the time.


Got it... I thinks.

Since it's an existing closed structure, I can pour from the back of the structure out to the front existing opening, pulling the pins as we come out... backfilling with the slurry... DOH! Confused

Like I said, Pandora's box...

I'd like your opinion on the slab finish... I'll probably pick a dye as opposed to grey... but, how hard of a finish should I get the contractor to power trowel? I'm gonna suspect that the harder, the better, but it's not like I do this for a livin' or anything!

Rod, I can't thank you enough!!!

Max

_________________
The insanity can be seen in bigger pix and greater detail at: http://www.dmmobile.com

"A committee is a cul-de-sac down which ideas are lured and then quietly strangled." -- Sir Barnett Cocks (1907 - 1989)
View user's profileSend private messageSend e-mailVisit poster's website
Rod Gervais
Moderator



Joined: Jun 8, 2003
Posts: 3188
Location: Central Village, CT


------------

Books To Read
Your Forum Posts

gimmie gear

PostPosted: Sun Apr 23, 2006 5:09 pm Reply with quoteBack to top

MadMax wrote:
I mis-quoted the depth of the existing gravel. It's not 1", it's more like 6-8" of crush-n-run... I just went out and tried to dig a test hole w/o much luck. Jebus is that stuff compacted and HARD!

Would 4" of sand in the haunch alone be sufficient?


Well it might - but that's the best I can tell you - I have always used it under the entire slab- which then damps the entire slab.

You can try it if you wish......... but I can't give any promises.....

Quote:
Got it... I thinks.

Since it's an existing closed structure, I can pour from the back of the structure out to the front existing opening, pulling the pins as we come out... backfilling with the slurry... DOH! Confused


We don't usually pull the pins until the concrete has set up enough to begin finishing.


Quote:
I'd like your opinion on the slab finish... I'll probably pick a dye as opposed to grey... but, how hard of a finish should I get the contractor to power trowel? I'm gonna suspect that the harder, the better, but it's not like I do this for a livin' or anything!


Max,

colors are up to you - as far as finish goes - I would want as flat and smooth as is possible......... a very good steel trowel finish is what you should buy..........

Rod

_________________
Rod Gervais
Acoustics Moderator Sometimes - late at night..... when the wind whips
through the trees........ and the moon shines bright in my
face......... I think deep thoughts.......... and my head hurts.
View user's profileSend private messageSend e-mail
MadMax
Recording Org
Pro Audio Group



Joined: Mar 18, 2001
Posts: 1340
Location: Sunny & warm NC


------------

Books To Read
Your Forum Posts

gimmie gear

PostPosted: Sun Apr 23, 2006 6:03 pm Reply with quoteBack to top

[quote="Rod Gervais"]Well it might - but that's the best I can tell you - I have always used it under the entire slab- which then damps the entire slab.

You can try it if you wish......... but I can't give any promises.....[quote]

Understood... Looks like I get to remove some of that crush-n-run. Oh joy.

Quote:
colors are up to you - as far as finish goes - I would want as flat and smooth as is possible......... a very good steel trowel finish is what you should buy..........


Just wasn't sure if there was any reason to get the contractor to do otherwise.

Thanx again,

Max

_________________
The insanity can be seen in bigger pix and greater detail at: http://www.dmmobile.com

"A committee is a cul-de-sac down which ideas are lured and then quietly strangled." -- Sir Barnett Cocks (1907 - 1989)
View user's profileSend private messageSend e-mailVisit poster's website
Display posts from previous:      
Post new topicReply to topic
View previous topic Log in to check your private messages View next topic



This topic sponsored by:

  Sound Performance Lab
(Tube, Mastering, Analog Gear)

  
  
  
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum



Powered by phpBB © 2001 phpBB Group

PHP-Nuke Port by Tom Nitzschner [Total Redesign By: Lorkan Themes] & 2004 www.toms-home.com
Pro Shop Cart
Your cart is empty.

[ Browse ]
Business Section
(News, Articles
Classifieds etc.)
· VocalBooth.com™ Gears Up for NAMM after a Year of Tremendous Growth
· New Rain LiveBook Audio Laptop With Up To 8GB RAM, Intel Montevina
· Artist Management Seminar - Washington DC
· Prime Loops Release Dirty Electro Synth Loops
· Free upgrade to Pro Tools 8 with any Digidesign LE product featuring 7.4.2
· Music Resources
· Eiosis releases AirEQ 5.1 Native and reduces the AirEQ's price
· Audio Impressions' announces Version 2.0 of DVZ Strings

[ More in News Section ]
Current Topics!
Last 10 Forum Messages

FINALLY!! The saga begins
Last post by MadMax in Studio Construction Forum on Dec 04, 2008 at 19:43:56

How diverse is the AT 4050
Last post by Cucco in Home, Project Studio's, Newbies on Dec 04, 2008 at 19:39:33

Magic disappearances through phase manipulation, by Remy...
Last post by ineedtolearnhowtorecord in Recording Forum on Dec 04, 2008 at 19:25:26

I thought Firewire was the "bling"
Last post by unclejemima in Digital Audio Forum on Dec 04, 2008 at 19:00:34

Need harsh critique
Last post by Space in Song & Mix Critique on Dec 04, 2008 at 18:51:21

Song Opinion
Last post by song4gabriel in Song & Mix Critique on Dec 04, 2008 at 18:44:08

Retube or Rent High Quality Preamp?
Last post by punkrocker in Recording Forum on Dec 04, 2008 at 18:29:13

VOICE PROBLEM
Last post by Kapt.Krunch in Digital Audio Forum</