the transformer most likely is 2:1...
this means 220V in = 110V out
or
240V in = 120V out
voila 8-)
Hi,
Kev sorry I'm turning to you in specific again but you're a fountain of knowledge when it comes to things electrical... and I don't know much about the electrical/electronic side of things..
I've just bought myself an OzAudio HM-6 headphone amp from US; it uses an internal transformer, I have contacted OzAudio (nice guys!) and they say it wants 120v.
I know I need a step-down transformer, and am looking at a 240-110v unit on eBay;
http://cgi.ebay.com.au/Step-down-tra...QQcmdZViewItem
I know 500W is overkill, but my main question is will this unit be okay, considering it's 110v output, and the headphone amp needs 120v?
Thanks in advance anyone!
Jonathan
the transformer most likely is 2:1...
this means 220V in = 110V out
or
240V in = 120V out
voila 8-)
It is always the same until someone changes it
Yes, that transformer will work nicely!
(FYI----I work in an electrical panel shop in PA)
15 years exp.
Cheers
basically the guys are correct
your specific question to,
" ... considering it's 110v output, and the headphone amp needs 120v? "
is sometimes valid and that subtle difference in voltages of
240, 230 and 220 for Aust / EU / British
and
10, 115 and 120 for the Americas
can cause unexpected issues
... I can explain if you want.
Guessing what might be inside this box I suspect a typical step down POWER transformer will probably satisfy.
This unit could also be handy to have for many things and yes 500 is strong. It will be usful if someone brings an American Guitar Amp to you.
just for comparison,
Jaycar CAT. NO. MF1084 500W
RRP $99.95
Jaycar CAT. NO. MF1086 1000W
RRP $129.00
Jaycar CAT. NO. MF1091 50VA
RRP $219.00
A second thought could be to change it internally.
All things are possible but I would have to see inside.
There may be a possible solder mod
OR
A simple replacment of the power torriod (if it has one ) for a 240V unit.
A complete guess ... but something like this
Jaycar CAT. NO. MT2086
RRP $21.95
BUT if it is PCB mount
!!!!
shut up Kev !!
:roll:
would need to see inside to know
Kev
DIY Factory
Thanks for the responses guys!
And don't shut up Kev, I appreciate your help whenever you offer it!
Funny you mention, I was thinking about internally modifying it, that way will save the need for any external transformers etc.
Should get the HP amp within a few days, I'll take a peek inside when I get it.
Hey Kev, got the unit, it just uses one of those laminated mains transformers... like this sort of thing, as far as I can tell anyway...
http://www.jaycar.com.au/productView...=&SUBCATID=411
Is it safe if I measure the voltage from each of the wires (5 coming out of it leading to the PCB) and get a 240v multitap transformer with enough current, and just replace it?
Do I have to worry about anything else, or is this a safe swap?
Thanks,
Jonathan
Yes
but it's a 110 input ?
oh
you are going to use the step down transformer and then measure the outputs of the internal.
Remember they are AC volts and you have 5 wires so it is likely you have two for lighting and three as the main Centre Tapped dual power supply.
This is only a guess and I would like to see inside.
Be careful
draw a picture and clearly write down your findings. Show where you had the probes ... cos you will forget tomorrow.
Don't touch things inside with the power on IF you don't know what you are doing.
Are you in Melbourne ?
Nah I'm in Tasmania :(
My old man is good with electronics, used to repair TVs/amps etc at one stage, but I only see him once every 2/3 weeks; I can solder (had practice on cables etc) and know some basic electronics, but if it requires more than just a drop-in replacement I'll get him to help me out.
Turns out I can't get hold of a stepdown transformer, so not sure what I can do. I may email OzAudio (they're very helpful!) and ask them what voltages come off the transformer... Actually I'll do that now.
I'll take some pictures tonight when I get home and post them, maybe you'd be able to tell me something!
Thanks,
Jonathan
I've opened up the unit and it's using a whole bunch of NJM4560 op amps. I downloaded the datasheet and it says they run from 4V to 18V.
Doesn't look like there's any other active components in there... do you think it'd be okay to run a 12V (secondary) CT transformer to replace the existing one? Would it matter if the secondary voltage was different than what the original transformer was, as long as it's within the specs for the opamps?
(oh by the way there's only 3 wires coming out of transformer, not 5 like I thought)
Bookmarks