Hello everyone,

I just bought a Copicat ic300 and it has a 2 core mains wire which means it's not grounded. I've had a look around the web but can't find instruction on how to ground it. Can anyone help? is it just as simple as replacing the 2 core to 3 core and connecting the ground to the case? or is there more to it (ie, inputs need grounding)?

Thanks in advance.

Viceroy is a cat

Comments

Boswell Mon, 06/02/2014 - 06:51

The Watkins ic300.jpe

for the original UK version of the Copicat 300 shows an earth connection (E) as well as the line and neutral. The E is connected to chassis. It's possible that the US and/or Canadian versions did not bring out a connection to the E point, but locating it or using the chassis point at the output jack and taking it to mains ground should work OK. I'm assuming in your unit the two mains transformer primaries are wired in parallel to give you a 120V mains input.

Boswell Mon, 06/02/2014 - 10:54

I used to have one of those units, and I know it had a 3-core mains lead on it. Where exactly the earth was attached at the equipment end I don't remember. If you open the unit up, you should see 3 terminal points with (presumably) the existing lead attached to 2 of them. It's a good guess that you would connect the earth wire to the third, but it would be worth checking with a continuity tester that the third terminal is indeed connected to the sleeve ground on the jack input and output sockets.

paulears Tue, 06/03/2014 - 12:57

As the unit has the chassis connected to the output socket ground, then what is your purpose in grounding it via the power cord? If you are looking for an electrical safety ground, then it's fine, but you can also be introducing the possibility of a ground loop, as you will have multiple ground paths. Before you replace the cable, why not simply test it by adding a ground and connecting to a loop of wire slid over the jack so when you stick it in, it makes contact? Any ground loops will reveal themselves and save you wasting time putting in a new cable. What do you mean by 'getting charged'? Nothing is getting charged. I wonder if you're concerned about static charge build up? This will not happen because the output socket will be a ground path anyway.

You know it's really quite difficult for a Brit (I wonder if Boswell has the same problem) to keep swapping words - like ground, for earth, and cord for lead.

anonymous Wed, 06/04/2014 - 04:47

paulears, post: 415387, member: 47782 wrote: You know it's really quite difficult for a Brit (I wonder if Boswell has the same problem) to keep swapping words - like ground, for earth, and cord for lead.

...and "pissed" for drunk instead of angry. And... I've had it up to here ( insert "up to here" emoticon) with you guys adding the letter U into words like color, labor, etc.

Oh...and chips instead of fries, crisps instead of chips... :confused:

The search for civilization continues... :p