Skip to main content

Hey,
I've received Pro Tools 7.1- 44.1khz sessions that were recorded at 48 khz using a Mackie desk as the master clock.. As well the opposite way around. So if I don't have a clock to control it. it plays at slower or faster speeds.

Is there anyway to fix this so the session sample rate matches the the clock I'm using.
Hope I worded it right.
Yhanks.

Comments

anonymous Sun, 06/24/2007 - 06:04

Dude.. U've made an error that should never happen in the future.. Coz now its only damage control..

Heres what u can try.. Open a new session at 48k & the rite bit rate.. Use the Import session data function from the file -> import menu.. Import all the tracks from the original session that u got at 44.1k.. While u do that, uncheck the box that says "Apply SRC". Or another option is that u could keep it checked & select 44.1k as the source sample rate.. (I'd go with the 1st option)

I havent really been in such a situation, but i guess this should work.. Lemme know how it goes..

Regards
Swapnil